Region / State
Canton of Vaud (Waadt)
Building Code
Vaud Cantonal Energy Law (LVLEne); CECB / Minergie Romandie
Competent Authority
Direction générale de l’environnement (DGE-DIREV Vaud)
Climate Profile
Lake Geneva basin (mild) to Vaud Alps (alpine, high snow loads)
Delivery Route
Supply + Site Supervision
Vaud Cantonal Energy Law (LVLEne); CECB / Minergie Romandie ← Country Framework

Steel Frame Homes: Canton of Vaud (Lake Geneva) | SerVilla

Vaud cantonal energy regulations, Lake Geneva microclimate considerations and seismic design (SIA 261).

Engineering & Building Physics for Canton of Vaud (Waadt)

Seismic safety in Lake Geneva basin, slope installation adaptations and dual-climate thermal insulation.

Climate & Frost Line
Lake Geneva basin (mild) to Vaud Alps (alpine, high snow loads)
Statutory Authority
Direction générale de l’environnement (DGE-DIREV Vaud)
Steel Grade
S350GD+Z275 (Eurocode 3 / EN 10346)

Microclimate & Passive Design Measures for Canton of Vaud (Waadt)

Engineering measures tailored to regional wind currents, humidity swings and solar radiation:

Solar Shading & Overheating Prevention

Triple-glazed windows with solar factor g ≤ 0.35 and rear-ventilated cavity facades protect interior comfort during peak summer months.

Wind & Snow Action Reinforcement

Engineered trusses and lateral cross-bracing designed per Eurocode 1 to resist localized wind gusts, suction pressures and snow drifts.

Thermal-Bridge Free Envelope

Continuous exterior insulation wraps the steel studs entirely, preventing condensation risks, condensation mold, and winter heat dissipation.

Division of Responsibilities in Canton of Vaud (Waadt)

SerVilla Off-Site Scope

Structural design to Eurocode 3, CAM roll-formed framing, continuous insulation build-ups, membranes, assembly plans and site supervision.

Local Registered Architect/Engineer

Permit submission to municipal planning authority, geotechnical survey, foundation slab engineering and local clerk of works.

Explore Other Model Concepts

Compare alternative footprints, storey options and spatial arrangements.

Important Note: Veranda, garage, terrace, pool, BASEMENT FLOOR, etc. are NOT included in areas & PRICES. Semi-detached / twin models: 1 unit basis.
Model 25-1003 — 99 m², 1 storey
Model 25-1003 Farmhouse & Ranch

Model 25-1003 • 99 m²

Model 25-1003 — 99 m², 1 storey

1 Storey
2 Bedrooms
1 Garage
Model 25-1004 — 114 m², 1 storey
Model 25-1004 American Style

Model 25-1004 • 114 m²

Model 25-1004 — 114 m², 1 storey

1 Storey
3 Bedrooms
1 Garage
Model 25-1005 — 135 m², 1 storey

Model 25-1005 • 135 m²

Model 25-1005 — 135 m², 1 storey

1 Storey
3 Bedrooms
0 Garage

Request a Project Consultation for Canton of Vaud (Waadt)

Tell us your building site in Canton of Vaud (Waadt), desired floor area and energy targets. Our engineering team will prepare a customized scope and delivery quote.

Request Quote for Canton of Vaud (Waadt) WhatsApp: +90 (505) 507 04 18

Frequently Asked Questions

Essential answers regarding steel construction, energy targets and project delivery.

Each country has specific energy performance regulations (e.g. GEG in Germany, RE2020 in France, Part L in Ireland). We design our steel envelope to comply with your local code requirements.

Statutory permits, local planning submissions, and national structural certification must be signed by a registered local architect or engineer in your jurisdiction.

Steel frame kits and building materials are packed into shipping containers or trucks. Transport and customs clearance terms (Incoterms like DAP or CIF) are detailed in each quote.

Yes. We offer experienced erection supervisors who oversee local assembly teams to ensure structural alignment and airtight envelope execution.

Yes. For Scandinavian and Alpine regions, wall insulation thicknesses can be increased up to 300-400mm with U-values down to 0.10 W/m²K.

Chat on WhatsApp