Standard
klimaaktiv
System Type
Voluntary building quality assessment
Steel Envelope Target
Full Thermal Decoupling
Airtightness Benchmark
n50 <= 0.60 h⁻¹
Verification Date
2026-09-12
Voluntary building quality assessment

klimaaktiv Energy Standards & Steel Frame | Passive Steel Homes

An Austrian building quality assessment covering energy alongside location, materials, health and comfort. It is separate from mandatory OIB requirements.

klimaaktiv Performance Benchmarks vs Standard Building
ISO / EN Verified
Heating Demand Standard Building: ~90 kWh ≤ 15 kWh (SerVilla) Airtightness (n50) Code Limit: 2.50 h⁻¹ 0.35 h⁻¹ (SerVilla) Window Uw (W/m²K) Double Glazing: 1.30 W/m²K 0.78 W/m²K (3 Cam) Thermal Bridge (Ψ) Concrete Beam: ~0.45 W/mK ≤ 0.010

klimaaktiv in Steel Frame Construction

An Austrian building quality assessment covering energy alongside location, materials, health and comfort. It is separate from mandatory OIB requirements.

Key Questions for Project Evaluation

Which rating level is requested? Can the project team provide the location, product and quality documentation for that level?

Applicable Countries & Adoption for klimaaktiv

European countries where this standard serves as a statutory code, subsidy benchmark, or accredited green label:

1 Countries Mapped

Austria

Edition / Verification
Austrian National Quality & Subsidy Standard
Local Framework: OIB Guideline 6; Provincial Building Regulations
View Austria Guide

Performance Benchmarks & Criteria for klimaaktiv

Voluntary building quality assessment
Performance Parameter Benchmark Target Steel Envelope Methodology
1000-Point Rating System Bronze: 700 | Silver: 750 | Gold: 900 Points Grade-A lightweight steel framing, top thermal wrap & comfort
Space Heating Demand (HWB) ≤ 15 – 25 kWh/m²a Substantially exceeds OIB-6 guideline with continuous rockwool
Ecological Material Benchmark Exclusion of PVC, HFCs and biocides 100% inorganic, mold-proof & zero-emission galvanized steel
Indoor Air Quality (VOC) TVOC ≤ 1000 µg/m³, Formaldehit ≤ 60 µg/m³ Mineral insulation & continuous F7-filtered mechanical fresh air
Airtightness (n50) Silber: ≤ 1.00 h⁻¹ | Gold: ≤ 0.60 h⁻¹ On-site Blower Door test confirms leak-free frame execution

Delivery Packages Compatibility for klimaaktiv

Required procurement scope and on-site interfaces to secure compliance with this standard:

Explore All Packages

P1 Structural Frame

Incomplete (Requires Envelope Package)

Supplies precision CFS steel frame and certified Eurocode statics dossier. Thermal insulation, airtight membranes, and high-performance fenestration must be procured and executed by your local site contractor.

P2 Frame + Cavity Insulation

Partial Shell (Requires Exterior EWI)

Includes structural steel studs, cavity rockwool infill and exterior structural sheathing. Meeting the stringent benchmark U-values of this standard requires additional continuous exterior rockwool wrap on site.

P3 Weather-Tight Envelope

Recommended / Certified Envelope Guarantee

The SWEET SPOT for Passive House & statutory low-energy standards. Features continuous exterior insulation wrap (U <= 0.11-0.14 W/m²K), certified triple-glazed fenestration, and airtight junction details securing n50 <= 0.60 h⁻¹.

P4 Complete Turnkey Kit

Fully Compliant / Complete Kit

Includes full P3 thermal envelope plus certified 85%+ MVHR ventilation unit, heat pump readiness, interior drywall lining assemblies, and sanitary/electrical rough-in components for 100% turnkey compliance.

STATE SUBSIDIES & GREEN FINANCE

Austria Provincial Housing Grants & klimaaktiv Gold Bonus

€20,000 - €45,000 Non-Repayable Grants & Provincial Concessions

Across Austrian federal states, achieving klimaaktiv Gold awards maximum environmental points in regional Wohnbauförderung schemes, securing direct non-repayable grants.

Calculate Subsidy & Costs Construction Cost Guide

Certification & Verification Roadmap for klimaaktiv

01
Dynamic Energy Simulation

PHPP or statutory calculation prepared with plot coordinates, solar azimuth, and local weather files.

02
Component Optimization

Target U-values specified with exterior rockwool thickness and triple-glazed warm-edge fenestration.

03
On-Site Blower Door Test

ISO 9972 pressure test and IR thermography physically verify airtightness threshold n50 <= 0.60 h⁻¹.

04
Accredited Certification

Third-party certified audit dossier submitted for official energy efficiency and green mortgage registration.

Why Cold-Formed Steel for klimaaktiv?

Dimensional Stability

Steel frame does not shrink, twist or warp, ensuring airtight seals and tape junctions remain permanently intact.

CAD/CAM Precision

Windows and panel interfaces are roll-formed to 0.5 mm tolerance, preventing unplanned thermal leaks on site.

100% Inorganic

Galvanized steel is impervious to rot, mold, fungi and termites, securing building biology credentials.

Consult on klimaaktiv Compliance for Your Plot

Review required U-values, envelope assemblies and delivery package scopes tailored to klimaaktiv.

Consult via WhatsApp

Explore Other Model Concepts

Compare alternative footprints, storey options and spatial arrangements.

Important Note: Veranda, garage, terrace, pool, BASEMENT FLOOR, etc. are NOT included in areas & PRICES. Semi-detached / twin models: 1 unit basis.
Model 25-1003 — 99 m², 1 storey
Model 25-1003 Farmhouse & Ranch

Model 25-1003 • 99 m²

Model 25-1003 — 99 m², 1 storey

1 Storey
2 Bedrooms
1 Garage
Model 25-1004 — 114 m², 1 storey
Model 25-1004 American Style

Model 25-1004 • 114 m²

Model 25-1004 — 114 m², 1 storey

1 Storey
3 Bedrooms
1 Garage
Model 25-1005 — 135 m², 1 storey

Model 25-1005 • 135 m²

Model 25-1005 — 135 m², 1 storey

1 Storey
3 Bedrooms
0 Garage

Frequently Asked Questions

Essential answers regarding steel construction, energy targets and project delivery.

Yes. With exterior continuous insulation eliminating thermal bridging, certified triple-glazed windows, airtight membranes, and heat recovery ventilation (MVHR), steel homes achieve full Passive House standards.

Thermal bridging is prevented by external continuous insulation wrap, thermal-break tape on structural connections, and decoupling outer claddings from interior framing.

Passive House requires n50 <= 0.6 h-1 on Blower Door testing. Our envelope design incorporates continuous vapor control membranes taped at all seams.

Minergie is a Swiss quality label focusing on energy efficiency and indoor comfort with specific primary energy criteria, while Passivhaus has strict heating demand caps (15 kWh/m²a).

Official building certifications are issued by accredited third-party certifiers (e.g. Passive House Institute, Minergie Agency, DGNB) upon submission of calculations and test results.

Request a Project Quote

Prepare your project brief and connect directly with the SerVilla engineering team via WhatsApp.

Direct connection with SerVilla engineering desk.
ℹ️ How it works: Clicking opens a pre-composed project brief in WhatsApp. You review and send it yourself. No payment or financial data is collected.
Chat on WhatsApp