Standard
Home Performance Index / Pathway
System Type
Voluntary housing sustainability assessment
Steel Envelope Target
Full Thermal Decoupling
Airtightness Benchmark
n50 <= 0.60 h⁻¹
Verification Date
2026-09-12
Voluntary housing sustainability assessment

Home Performance Index / Pathway | SerVilla

Ireland’s HPI assesses broader housing sustainability. Pathway provides an entry route aimed at smaller developers; project eligibility requires confirmation.

Home Performance Index / Pathway Performance Benchmarks vs Standard Building
ISO / EN Verified
Heating Demand Standard Building: ~90 kWh ≤ 15 kWh (SerVilla) Airtightness (n50) Code Limit: 2.50 h⁻¹ 0.35 h⁻¹ (SerVilla) Window Uw (W/m²K) Double Glazing: 1.30 W/m²K 0.78 W/m²K (3 Cam) Thermal Bridge (Ψ) Concrete Beam: ~0.45 W/mK ≤ 0.010

Home Performance Index / Pathway in Steel Frame Construction

Ireland’s HPI assesses broader housing sustainability. Pathway provides an entry route aimed at smaller developers; project eligibility requires confirmation.

Key Questions for Project Evaluation

Is HPI or Pathway appropriate for this residential project? How will its evidence be coordinated with the separate BER process?

Applicable Countries & Adoption for Home Performance Index / Pathway

European countries where this standard serves as a statutory code, subsidy benchmark, or accredited green label:

1 Countries Mapped

Ireland

Verified Framework
National Standard of Irish Green Building Council
Local Framework: Building Regulations Part L; NZEB; DEAP Methodology
View Ireland Guide

Performance Benchmarks & Criteria for Home Performance Index / Pathway

Voluntary housing sustainability assessment
Performance Parameter Benchmark Target Steel Envelope Methodology
Space Heating / Cooling Demand ≤ 15 – 35 kWh/m²a Continuous exterior mineral wool wrap + triple glazing
Airtightness (n50) ≤ 0.60 – 1.00 h⁻¹ (50 Pa) Variable vapor control membrane & continuous taping
Thermal Bridge Coefficient (Psi) Ψ ≤ 0.010 W/mK Continuous exterior insulation wrapping CFS frame completely
Mechanical Ventilation (MVHR) ≥ 75% – 85% Recovery Acoustically insulated MVHR system with F7 fine filtration
Summer Comfort / Overheating ≤ 10% (> 25°C) Exterior motorized solar blinds & architectural roof overhangs

Delivery Packages Compatibility for Home Performance Index / Pathway

Required procurement scope and on-site interfaces to secure compliance with this standard:

Explore All Packages

P1 Structural Frame

Incomplete (Requires Envelope Package)

Supplies precision CFS steel frame and certified Eurocode statics dossier. Thermal insulation, airtight membranes, and high-performance fenestration must be procured and executed by your local site contractor.

P2 Frame + Cavity Insulation

Partial Shell (Requires Exterior EWI)

Includes structural steel studs, cavity rockwool infill and exterior structural sheathing. Meeting the stringent benchmark U-values of this standard requires additional continuous exterior rockwool wrap on site.

P3 Weather-Tight Envelope

Recommended / Certified Envelope Guarantee

The SWEET SPOT for Passive House & statutory low-energy standards. Features continuous exterior insulation wrap (U <= 0.11-0.14 W/m²K), certified triple-glazed fenestration, and airtight junction details securing n50 <= 0.60 h⁻¹.

P4 Complete Turnkey Kit

Fully Compliant / Complete Kit

Includes full P3 thermal envelope plus certified 85%+ MVHR ventilation unit, heat pump readiness, interior drywall lining assemblies, and sanitary/electrical rough-in components for 100% turnkey compliance.

STATE SUBSIDIES & GREEN FINANCE

International Green Building Finance & ESG Capital

Green Mortgage Eligibility & High Residual Value

Cold-formed steel homes certified to this performance benchmark qualify for European green mortgage products and command a 15-25% premium in market liquidity and asset preservation.

Calculate Subsidy & Costs Construction Cost Guide

Certification & Verification Roadmap for Home Performance Index / Pathway

01
Dynamic Energy Simulation

PHPP or statutory calculation prepared with plot coordinates, solar azimuth, and local weather files.

02
Component Optimization

Target U-values specified with exterior rockwool thickness and triple-glazed warm-edge fenestration.

03
On-Site Blower Door Test

ISO 9972 pressure test and IR thermography physically verify airtightness threshold n50 <= 0.60 h⁻¹.

04
Accredited Certification

Third-party certified audit dossier submitted for official energy efficiency and green mortgage registration.

Why Cold-Formed Steel for Home Performance Index / Pathway?

Dimensional Stability

Steel frame does not shrink, twist or warp, ensuring airtight seals and tape junctions remain permanently intact.

CAD/CAM Precision

Windows and panel interfaces are roll-formed to 0.5 mm tolerance, preventing unplanned thermal leaks on site.

100% Inorganic

Galvanized steel is impervious to rot, mold, fungi and termites, securing building biology credentials.

Consult on Home Performance Index / Pathway Compliance for Your Plot

Review required U-values, envelope assemblies and delivery package scopes tailored to Home Performance Index / Pathway.

Consult via WhatsApp

Explore Other Model Concepts

Compare alternative footprints, storey options and spatial arrangements.

Important Note: Veranda, garage, terrace, pool, BASEMENT FLOOR, etc. are NOT included in areas & PRICES. Semi-detached / twin models: 1 unit basis.
Model 25-1003 — 99 m², 1 storey
Model 25-1003 Farmhouse & Ranch

Model 25-1003 • 99 m²

Model 25-1003 — 99 m², 1 storey

1 Storey
2 Bedrooms
1 Garage
Model 25-1004 — 114 m², 1 storey
Model 25-1004 American Style

Model 25-1004 • 114 m²

Model 25-1004 — 114 m², 1 storey

1 Storey
3 Bedrooms
1 Garage
Model 25-1005 — 135 m², 1 storey

Model 25-1005 • 135 m²

Model 25-1005 — 135 m², 1 storey

1 Storey
3 Bedrooms
0 Garage

Frequently Asked Questions

Essential answers regarding steel construction, energy targets and project delivery.

Yes. With exterior continuous insulation eliminating thermal bridging, certified triple-glazed windows, airtight membranes, and heat recovery ventilation (MVHR), steel homes achieve full Passive House standards.

Thermal bridging is prevented by external continuous insulation wrap, thermal-break tape on structural connections, and decoupling outer claddings from interior framing.

Passive House requires n50 <= 0.6 h-1 on Blower Door testing. Our envelope design incorporates continuous vapor control membranes taped at all seams.

Minergie is a Swiss quality label focusing on energy efficiency and indoor comfort with specific primary energy criteria, while Passivhaus has strict heating demand caps (15 kWh/m²a).

Official building certifications are issued by accredited third-party certifiers (e.g. Passive House Institute, Minergie Agency, DGNB) upon submission of calculations and test results.

Request a Project Quote

Prepare your project brief and connect directly with the SerVilla engineering team via WhatsApp.

Direct connection with SerVilla engineering desk.
ℹ️ How it works: Clicking opens a pre-composed project brief in WhatsApp. You review and send it yourself. No payment or financial data is collected.
Chat on WhatsApp