Window Uw Target
Uw <= 0.80 W/m²K
Glass Ug Target
Ug = 0.50 - 0.60 W/m²K
Solar Factor (g)
g = 0.50 - 0.55 (Kışın Kazanç)
Cavity Gas Fill
%90+ Saf Argon
Spacer Technology
Swisspacer Ultimate (Warm-Edge)
Solar Shading
Dış Jaluzi / Zip Perde (Fc: 0.15)
PHI Certified Triple-Glazing & Warm Edge (Uw <= 0.80 W/m²K)

Windows and summer shading | SerVilla

Prepare an opening schedule with sizes, orientation, frame and glazing specification, installation details and shading proposals.

Engineering Drawing & Physical Cross-Section
CAD/CAM Scale 1:1 Reference
TRIPLE LOW-E GLAZING & EXTERNAL SOLAR SHADING DETAIL Ug = 0.50 W/m²K • Swisspacer Warm Edge • Motorized Aluminum Raffstore (Fc = 0.15) 6-Chamber Passive Frame 16mm Argon 16mm Argon Swisspacer Warm Edge SUMMER: 85% OF SOLAR HEAT BLOCKED OUTSIDE Raffstore Cassette Reflected Solar Heat (85%) Diffused Daylight (15%) Uw ≤ 0.80 W/m²K • Ug = 0.50 W/m²K • g = 0.53 Interior glass surface stays at 18°C in winter; perimeter radiators are unnecessary.
LIVE SIMULATOR

Triple Glazing & Dynamic Shading Simulator

ISO / EN Compliant Math

Select glazing build, warm-edge spacer, and exterior shading systems to calculate net window Uw, summer solar heat gain (gtot), and overheating risk.

Window U-Value (Uw)
0.78 W/m²K
PHI CLASS phA (≤0.80)
Solar Factor (gtot)
0.09
91% Solar Heat Rejected
Overheating Risk (>25°C)
%1.8
DIN 4108-2 Compliant (≤ 10%)
Internal Glass Edge Temp
17.6 °C
Zero Condensation & Mold
1:1 CAD/CAM Detail Eurocode 3 • Passivhaus • DIN 4108

Interactive Architectural Sections & Junction Details

Explore the layer-by-layer anatomy of walls, floors, foundations, roofs and precision window installation interfaces.

✓ 1 Systems • High-Precision Details

Window Detail A: Head & Concealed Blind Box

Concealed external venetian blind (raffstore) box recessed directly into exterior insulation with high-performance back-insulation, eliminating lintel thermal bridges.

Ψhead ≤ 0.015 W/mK • Integrated Blind Box • Zero Thermal Bridge
Head Thermal Bridge (Ψ)
Ψ ≤ 0.015 W/mK
Blind Box Insulation
40 mm High-Efficiency PIR (λ=0.022)
Internal Airtight Tape
Pro Clima Contega Solido SL
CAD/CAM PRECISION • CROSS SECTION 1:1 VECTOR SPEC ONLINE INTERACTIVE
WINDOW HEAD LINTEL & CONCEALED EXTERNAL BLIND DETAIL Ψhead ≤ 0.015 W/mK 4 2 3 6 LINTEL & CONCEALED BLIND SPECIFICATION: [2] Motorized Aluminium Raffstore / External Blind Box (130 mm) [3] 40 mm PIR Thermal Insulation Barrier behind Box (λ=0.022) [4] CFS Box Lintel (Twin C140 Pre-Engineered Studs) [5] 3-Tier RAL Sealing Tapes • Red Airtight Line Tie-In [6] Üç Camlı Pasif Ev Doğrama Üst Kasası (Uw ≤ 0.80) LINTEL INSTALLATION DETAIL Ψhead ≤ 0.015 W/mK • Thermal-Bridge-Free Concealed External Shading

Physical Layer Breakdown & Material Specification

6 Layers
1 Exterior Render & Stop Bead
P3
10 mm λ: 0.75 W/mK μ: 35 A2-s1,d0
Exterior render with plaster stop drip bead
2 Concealed Motorized Raffstore / Venetian Blind Box
P3
130 mm λ: 0.18 W/mK μ: Sonsuz A1
Concealed motorized Venetian blind box
3 High-Performance PIR Thermal Backer (λ=0.022)
P3
40 mm λ: 0.022 W/mK μ: 60 B-s2,d0
High-performance PIR thermal bridge shield
4 CFS Double C140 Structural Box Lintel
P1
140 mm λ: 50 W/mK μ: Sonsuz A1
Engineered cold-formed steel header / box lintel
5 3-Tier RAL Window Head Sealing Tapes
P3
Standart λ: 0.035 W/mK μ: Sd=0.05 - 15m B1 / E
RAL 3-tier airtight & weather-tight sealing tapes
6 Passive House Certified Triple-Glazed Top Frame
P3
88 mm λ: 0.11 W/mK μ: Sonsuz B2
Passivhaus certified triple-glazed window frame
Scroll horizontally to view all layer parameters 6 Layers
No Material & Layer Specification Thickness Conductivity (λ) Vapour / Sd Fire Class Delivery Package Building Physics Function
1 Exterior Render & Stop Bead 10 mm 0.75 W/mK 35 A2-s1,d0 P3 Exterior render with plaster stop drip bead
2 Concealed Motorized Raffstore / Venetian Blind Box 130 mm 0.18 W/mK Sonsuz A1 P3 Concealed motorized Venetian blind box
3 High-Performance PIR Thermal Backer (λ=0.022) 40 mm 0.022 W/mK 60 B-s2,d0 P3 High-performance PIR thermal bridge shield
4 CFS Double C140 Structural Box Lintel 140 mm 50 W/mK Sonsuz A1 P1 Engineered cold-formed steel header / box lintel
5 3-Tier RAL Window Head Sealing Tapes Standart 0.035 W/mK Sd=0.05 - 15m B1 / E P3 RAL 3-tier airtight & weather-tight sealing tapes
6 Passive House Certified Triple-Glazed Top Frame 88 mm 0.11 W/mK Sonsuz B2 P3 Passivhaus certified triple-glazed window frame
Delivery Package Demarcation Lines:
P1: P1: Structural Light Gauge Steel Frame & Anchors
P2: P2: Frame + Sheathing + Cavity Insulation + Vapour Control
P3: P3: Weather-Tight Shell (Continuous EWI + Windows + Roof Waterproofing)
P4: P4: Internal Service Zone + Screed + Double Lining / Finishes

All cross-sections are engineered to Passive House Institute (PHI) standards, Eurocode 3 cold-formed steel rules and DIN 4108 condensation criteria. Contact our engineering desk for project-specific calculations.

Discuss This Section With Our Engineers

Technical Specifications & International Standards

Design criteria verified against Eurocode, ISO and DIN standards.

Verified Assembly
Component / Specification Engineering Details Standard Reference Performance Advantage
Triple Insulated Glass Unit 4 Low-E / 16 Ar / 4 Float / 16 Ar / 4 Low-E (48 mm overall thickness) EN 1279 / EN 673 Ug = 0.50 W/m²K; interior glass surface stays warm (>17°C)
Insulated Frame System 6-7 Chamber PVC-U (Schüco / Kömmerling) or Thermal Timber-Aluminum EN 10077-2 / PHI Sınıfı phA Uf = 0.75 - 0.85 W/m²K with triple continuous EPDM gaskets
Warm Edge Spacer Technology Composite plastic-stainless steel spacer (Swisspacer Ultimate) EN ISO 10077-1 Eliminates edge condensation and frost along glazing perimeter
External Solar Shading (Raffstores) Motorized Aluminum External Venetian Blinds (Raffstore) or Wind-Resistant Zip Screen DIN 4108-2 (Sommerlicher Wärmeschutz) Blocks 85% of solar heat before reaching glass (shading factor Fc = 0.15)
In-Insulation Installation Thermal composite pre-wall brackets cantilevered beyond steel framing RAL-Montage / ISO 10211 Minimizes perimeter thermal bridging to Psi <= 0.015 W/mK
PHYSICS PROOF

EN ISO 10077-1 Total Window U-Value (Uw) Calculation

$$ U_w = \frac{A_g U_g + A_f U_f + l_g \Psi_g}{A_g + A_f} = \frac{1.75(0.50) + 0.55(0.80) + 5.6(0.030)}{2.30} = 0.775 \ \text{W/m}^2\text{K} $$

For a standard 1.23 x 1.48 m test window (total 2.30 m²): Triple Low-E glass area 1.75 m² (Ug = 0.50), insulated frame 0.55 m² (Uf = 0.80) and Swisspacer Ultimate warm edge spacer (Ψg = 0.030). The resulting composite Uw = 0.78 W/m²K qualifies for Passivhaus certified component status (phA).

Failure Mode Analysis: Conventional Errors vs SerVilla Mitigation

Comparative building physics study showing failure points avoided by SerVilla design.

RISK MITIGATION
Relying on Interior Curtains to Block Summer Solar Heat DIN 4108-2 / EN 13363-1
Conventional Failure Risk

Solar radiation entering through glass traps heat inboard (greenhouse effect); interior curtains fail to prevent room temperatures exceeding 35°C.

SerVilla Engineering Solution

Motorized external Z-slat Raffstore blinds deflect 85-90% of solar radiation outside the thermal envelope (effective gtot <= 0.10).

Using Conventional Aluminum Glazing Spacers Causing Edge Condensation EN ISO 10077-1
Conventional Failure Risk

Aluminum conducts cold directly into the glass rim; moisture trickles down windows, damaging sills and fostering mold spores.

SerVilla Engineering Solution

Swisspacer Ultimate composite warm-edge spacers (Psi_g = 0.030 W/mK) maintain internal glass edge temperature well above 17°C.

BIM LEVEL 2 / OPENBIM SPECIFICATION

BIM Specification & Structural Data Sheet

IFC 4 / ISO 16739-1
IFC Data Schema
IFC 4 Window Assembly (IfcWindow / Pset_WindowCommon)
Fire Reaction Class
EN 13501-2 EI 30 / EW 30 (Optional Fire Glazing)
Acoustic Sound Index
Rw = 44 dB Sound Insulation (Acoustic PVB Laminated)
Durability & Lifetime
Wind Resistance Class C5 (EN 12210) / Watertight Class 9A
CE Declaration of Performance
PHI Component Certificate Class phA / EN 14351-1 CE
Material Specification
Triple Glazing 4-18-4-18-4 Argon 90% Low-E + Swisspacer Ultimate

Governing Standards & Eurocode Norms

Uw <= 0.80 W/m²K certified triple-glazed fenestration paired with exterior automated venetian shading.

EN ISO 10077-1 EN 1279 DIN 4108-2 (Sommerlicher Hitzeschutz)
Passive House / Passivhaus Minergie, Minergie-P, Minergie-A and ECO KfW / Effizienzhaus 40–55 CasaClima / KlimaHaus and Nature RE2020

Solar Heat Gain & Summer Comfort Physics

01

Net Energy Gain in Winter

South-facing triple-glazed windows collect more free passive solar heat through solar gain (g >= 50%) than they lose.

02

External Shading is Non-Negotiable

Internal blinds trap heat indoors. Exterior automated louvres reflect radiation before glass contact, stopping overheating.

03

Elimination of Radiant Cold Chills

Inner glass temperature stays at 17.5°C when outdoor is -10°C, eliminating downdraft chills and perimeter radiators.

04

RAL Certified 3-Layer Sealing

Sealed with interior airtight tape, flexible acoustic foam core and breathable weather-tight exterior band.

5-Point On-Site Quality Assurance Checklist

1
Glazing Label Verification: Certified 4-16Ar-4-16Ar-4 Low-E unit with verified 90%+ argon cavity concentration.
2
Warm Edge Spacer Inspection: Swisspacer Ultimate thermal spacer confirmed around entire glass perimeter.
3
Pre-Wall Bracket Mounting: Windows anchored via thermal composite sub-frames rather than direct metal-to-metal screws.
4
Raffstore Wind Sensor Integration: Automated solar blinds tested for obstacle detection and automatic storm retraction.
5
Weep-Hole & Gasket Calibration: Compression gaskets and drainage paths checked for watertight performance.

5. Triple-Glazed Passive Fenestration & Automated Solar Shading

In passive house architecture, windows are not merely daylight openings—they function as net-positive passive solar collectors. SerVilla triple-glazed systems capture more solar radiation during winter days than they lose via thermal transmission across 24 hours.

Technical Glazing & Framing Specifications

  • Triple IGU Assembly (Ug = 0.50 W/m²K]: 48 mm dual Low-E, dual argon-filled cavity (4-16Ar-4-16Ar-4]. Inner pane temperature never drops below 17.5°C when outside ambient drops to -10°C, eliminating downdraft chills and perimeter radiators.
  • Warm Edge Spacer Technology: Swisspacer Ultimate composite thermal spacers replace metallic aluminum, virtually eliminating edge condensation and mold around the perimeter glass seal.
  • Thermally Decoupled Frames (Uf = 0.75 - 0.85 W/m²K]: Multi-chamber steel-reinforced uPVC or timber-aluminum composite profiles achieving overall Uw <= 0.80 W/m²K (Passivhaus phA class].

Exterior Automated Solar Shading (Raffstores & Zip-Screens]

Preventing summertime overheating requires blocking direct radiation on the exterior side of the glass. SerVilla specifies motorized exterior Venetian blinds (Raffstores] or heavy-duty architectural zip-screens on south and west facades. With a solar shading coefficient of Fc = 0.15, 85% of solar heat is intercepted externally without reliance on intensive active AC cooling.

SerVilla Engineering Note: Details documented in this specification are engineered project-specifically based on local soil conditions, statutory climate data, wind/snow loads and chosen energy targets (PHI, KfW 40, Minergie). Certified execution drawings govern contracts.

Consult Our Engineering Desk on This Technical Assembly

Receive preliminary thermal bridging calculations and structural CFS advice directly from our senior engineering team.

Consult via WhatsApp

Explore Other Model Concepts

Compare alternative footprints, storey options and spatial arrangements.

Important Note: Veranda, garage, terrace, pool, BASEMENT FLOOR, etc. are NOT included in areas & PRICES. Semi-detached / twin models: 1 unit basis.
Model 25-1003 — 99 m², 1 storey
Model 25-1003 Farmhouse & Ranch

Model 25-1003 • 99 m²

Model 25-1003 — 99 m², 1 storey

1 Storey
2 Bedrooms
1 Garage
Model 25-1004 — 114 m², 1 storey
Model 25-1004 American Style

Model 25-1004 • 114 m²

Model 25-1004 — 114 m², 1 storey

1 Storey
3 Bedrooms
1 Garage
Model 25-1005 — 135 m², 1 storey

Model 25-1005 • 135 m²

Model 25-1005 — 135 m², 1 storey

1 Storey
3 Bedrooms
0 Garage

Frequently Asked Questions

Essential answers regarding steel construction, energy targets and project delivery.

While double-glazing achieves Ug values around 1.1-1.4 W/m²K, modern triple-glazed argon units achieve Ug = 0.5-0.6 W/m²K (over 2.5 times more insulative). With double-glazing in winter, the inner glass surface cools down to 10-12°C, inducing radiant draft. Triple-glazing keeps inner glass warm (17-18°C), completely eliminating cold air drop.

Super-insulated homes can overheat if solar gains are unmanaged. SerVilla integrates external motorized Venetian blinds (Raffstores) or exterior zip-screens on south and west elevations. Shading the exterior glass reflects up to 85% of solar radiation before it enters the home, maintaining cool interiors without heavy AC usage.

Standard IGUs utilize metallic aluminum spacers that act as thermal conductors along the perimeter of the glass pane, generating condensation and mold. Our Swisspacer composite spacers provide thermal resistance at the edge of the glass, elevating perimeter temperatures and eliminating condensation.

Both deliver certified Passive House performance (Uw <= 0.80 W/m²K). Premium multi-chamber uPVC frames offer outstanding cost-to-performance ratios and zero maintenance. Timber-aluminum composite frames provide the tactile warmth of natural wood inside and powder-coated architectural durability outside.

Standard sliding doors leak air because they rely on brush seals. In contrast, our Lift-and-Slide (Hebeschiebe) systems drop the moving sash into compressed multi-point EPDM gaskets when locked, achieving verified Class 4 airtightness matching fixed glazing performance.

Request a Project Quote

Prepare your project brief and connect directly with the SerVilla engineering team via WhatsApp.

Direct connection with SerVilla engineering desk.
ℹ️ How it works: Clicking opens a pre-composed project brief in WhatsApp. You review and send it yourself. No payment or financial data is collected.
Chat on WhatsApp